Aerotek logo

Aerotek AVP-300
Aerotek ACС-870TVAB

Aerotek Air Conditioner Error Codes

Error codes of air conditioners of the brand Aerotek

 

Aerotek produces climate equipment that does not

Is inferior to modern world analogues and possesses quite reasonable prices.

All products are distinguished by the optimal "price-quality" ratio. For

Production of air conditioners of this brand used components

Only high quality. Therefore, for all equipment of the company

The warranty is 3 years. Air-conditioners of Aerotek have a high level of reliability.

 

E0 - there was an error in determining the flow rate of water;

 

E1 - an error occurred while connecting the phases;

 

E2 - a communication error has occurred;

 

E3 - there was a mistake in the temperature sensor of the cooling liquid at the outlet;

 

E4 - a water temperature sensor error occurred when exiting from

Shell-and-tube heat exchanger;

 

E5 - an error occurred in the temperature sensor of the tubes of capacitor A;

 

E6 - there was an error in the temperature sensor of the tubes of the capacitor B;

 

E7 - an error occurred in the outdoor temperature sensor;

 

E8 - an error occurred in the temperature sensor in the discharge line

Compressor system A;

 

E9 - an error occurred while determining the water flow;

 

EA - the main unit recorded a decrease in the number of additional blocks;

 

EB - an error occurred in the temperature sensor of the protection system

Freezing of the heat exchanger;

 

EU - there is no output of one of the modular units;

 

ED - there was a communication error between the modular unit and the drive controller;

 

Ed - protection of electrical supply;

 

EE - there was a communication error between the computer and the drive controller;

 

EF - an error occurred in the temperature sensor at the water inlet;

 

P0 - there was an overheating in the injection line of system A;


Р1 - there was a pressure decrease in system A;

 

P2 - there was an overheating in the injection line of system B;

 

P3 - there was a decrease in pressure in the B system;

 

P4 - overcurrent occurred in system A;

 

P5 - overcurrent occurred in system B;

 

P6 - there was an increase in pressure in the condenser of system A;

 

P7 - the pressure in the capacitor of system B has increased;

 

P8 - errors occurred in the temperature sensor in the discharge line

Compressor system A;

 

P9 - protection against the difference in temperature of the water at the outlet and inlet;

 

RA - protection against supercooling during start-up;

 

Рb - there was a frost;

 

PE - the shell-and-tube heat exchanger was supercooled;

 

F1 - errors in permanent memory;

 

F2 - errors occurred when connecting the wired controllers.