This air conditioner is equipped with a self-diagnosis function to help you identify potential problems. Should you encounter problems with your air conditioner,
contact our after sales support centre using the details on the bottom of the page. However, before calling for service, consult the selfdiagnosis information below.
Indicates “dF”or heating icon blinks:Blinks once per second:Defrost indication
Fan motor picture not running:Blinks once per second:Anti cold wind
E2:Blinks once every 8 seconds:Room temperature sensor fault
E3:Blinks twice every 8 seconds:Coil temperature sensor
E8:Blinks 3 times every 8 seconds:Indoor fan fault
E5:Blinks 6 times every 8 seconds:Outdoor feedback
E7:Blinks 7 times every 8 seconds:External feedback fault
E0:Blinks 3 times every 8 seconds:Open the door fault
E1:Blinks 4 times every 8 seconds:Outdoor tube temperature sensor faults
E6:Blinks 6 times every 8 seconds:(EEPROM) Communication failures
FF:Blinks once per second:Outdoor temperature exceeds scope (too cold)