Bosch Gas Boiler Error Codes

Display Description Remedy

 

A7 The hot water temperature sensor is defective.

Check for damage or short circuit to the temperature sensor and its wire, replace if necessary

Ad The boiler temperature sensor is not recognized.

Check the boiler temperature sensor and the connection cable

C1 Low fan speed.

Check the mains voltage.

Check the flue gas system and clean or repair if necessary.

C4

Differential pressure switch not

Opens when the fan is off.

Check the differential pressure switch.

C6

Differential pressure switch not

Closes.

Check the fan and its wire with the plug, replace it with

Necessity.

Check the differential pressure switch and drain pipe

Flue gases.

C7 The fan does not work.

Check the fan and its wire with the plug, replace it with

Necessity.

CE

Insufficient filling pressure

Heating system.

Top up with water.

D7 The gas fitting is defective.

Check the connecting cable.

Check the gas fitting, replace if necessary.

E2

Faulty flow temperature sensor

Line (break).

Check for damage or short circuit

The temperature sensor and its wire,

Necessity.

E9

Temperature limiter tripped

Heat exchanger.

Check for damage to the temperature limiter

Heat exchanger and its connecting wire, replace with

Necessity.

Check the working pressure in the heating system.

Check the temperature limiter, if necessary

Replace.

Check pump start, replace pump if necessary.

Check fuse, replace if necessary

Bleed the boiler.

Check the water circuit of the heat exchanger, if necessary

Replace.

Check for damage to the temperature limiter

Flue gases.


EA Flame not detected.

Check the connection of the protective conductor.

Check that the gas cock is open.

Check the gas supply pressure, correct at

Necessity.

Check the connection to the mains.

Check the electrodes with wires, if necessary

Replace.

Check the flue gas system, if necessary

Clean or repair.

Check gas adjustment, correct if necessary.

For natural gas: check the gas flow monitoring relay,

Replace if necessary.

When working with a combustion air intake from a room

Check the air supply to the room and the ventilation

Holes.

Clean the heat exchanger.

Check the gas fitting, replace if necessary.

F7 Although the boiler is turned off, a flame is detected.

Check the contamination of the electrodes, if necessary

Replace.

Check the flue gas system, if necessary

Clean or repair.

Check the humidity of the electronic board, dry with

Necessity.

FA

After switching off the gas supply, it is detected

flame.

Check the gas fitting, replace if necessary.

Check the electrodes and connecting wires when

Need to replace.

Check the flue gas system, if necessary

Clean or repair.

| | | | The fan stage has not been set. Set the fan stage.

P The boiler type is not defined. Set boiler type

Fd

Button was mistakenly pressed for too long

(More than 30 seconds).

Press the button again for less than 30 seconds.