Daikin logo

Daikin Air-Conditioner Error Codes

Inverter air conditioner Daikin FTXG50LW
Daikin FTXN50L9 Air Conditioner

Indoor unit:

 

A0 - the common protective device has tripped

 

A1 - The indoor circuit board is faulty

 

A2 - the fan motor is blocked

 

A3 - an inadmissible level in the drainage system

 

A4 - defective heat exchanger

 

A5 - heat exchanger overheating

 

A6 - the fan motor is overloaded

 

A7 - shutter drive defective

 

A8 - current overload (common)

 

A9 - the electronic expansion valve is defective

 

AA - overheated heater

 

AH - the air filter clogged

 

AC - running idle work

 

AJ - Performance is incorrect (internal block)

 

AE - not enough water supply

 

AF - Damage to the humidifier

 

C0 - common sensor fault

 

C3 - Drainage level sensor defective

 

C4 - heat exchanger temperature sensor 1 defective

 

C5 - heat exchanger temperature sensor 2 defective

 

C6 - the fan motor is overloaded, the sensor is blocked

 

C7 - Shutter drive sensor out of order

 

C8 - input current sensor out of order

 

C9 - breakdown of the incoming air thermistor

 

CA - failure of the output air thermistor

 

CH - the dirt sensor works

 

CC - humidity sensor breakdown

 

CJ - the temperature sensor on the remote control does not work

 

CE - Radiation sensor failure

 

CF - high pressure sensor out of order


Outdoor unit:

 

E0 - the common protective device has tripped

 

E1 - The outdoor unit PCB is faulty

 

E3 - operates HPS (high pressure sensor)

 

E4 - runs LPS (low pressure sensor)

 

E5 - Compressor motor overloaded, overheating relay tripped

 

E6 - Compressor motor is blocked by overcurrent

 

E7 - the fan motor is blocked by overcurrent

 

E8 - current overload (common)

 

E9 - electronic expansion valve defective

 

AH - the pump is blocked

 

EC - peak water temperature

 

EJ - Additional protection device has tripped

 

EE - critical water level in the drainage system

 

EF - failure of the heat storage unit

 

H0 - common sensor fault

 

H1 - air temperature sensor defective

 

H2 - system power supply is defective

 

H3 - high pressure sensor defective

 

H4 - low pressure sensor defective

 

H5 - overload, compressor stop

 

H6 - compressor overload, the system is locked

 

H7 - fan overload, the system is locked

 

H8 is the drop in the input voltage

 

H9 - anomalous inlet air temperature

 

HA - abnormal outlet air temperature

 

HH - water pump blocked

 

HC - signal of the hot water sensor

 

HE - signal of the drainage level sensor

 

HF - heat storage unit higher than failure

 

F0 - protective system devices No.1 and No.2 function

 

F1 - the protective system device №1 is functioning

 

F2 - the protective system device №2 is functioning

 

F3 - abnormally high discharge pipe temperature

 

F6 - Inadmissible temperature in the heat exchanger

 

FA - unacceptable discharge air pressure

 

FH - overheating of oil

 

FC - Inadmissible intake air pressure

 

FE - unacceptable oil pressure

 

FF - unacceptable oil level indicator

 

J0 - thermistor defective

 

J1 - General malfunction of the pressure sensor

 

J2 - current sensor defective

 

J3 - breakdown of the temperature sensor of the air injection pipe

 

J4 - the sensor is not working at the saturation point of low pressure

 

J5 - the thermistor is defective on the suction pipe

 

J6 - the thermistor is defective on the heat exchanger (1)

 

J7 - the thermistor is defective on the heat exchanger (2)

 

J8 - the thermistor is faulty on the liquid pipe

 

J9 - thermistor defective on gas pipe

 

JA-discharge sensor defective

 

JH - temperature sensor mass defective

 

JC - suction pressure sensor defective

 

JE - oil pressure switch defective

 

JF - oil level sensor defective

 

L0 - the inverter system is faulty

 

L3 - control box temperature increased

 

L4 - the temperature of the power transistor heatsink is increased

 

L5 - short-time overload of DC output

 

L6 - short-time overload of alternating current at the output

 

L7 - common input current high

 

L8 - electronic thermal relay delay

 

L9 - safety stop

 

LA - power transistor failure

 

LC - disconnection from the inverter in the outdoor unit

 

P0 - lack of gas (due to icing of heat storage equipment)

 

P1 - no phase, power supply in unbalance

 

P3 - overheating of the control unit

 

P4 - the power transistor (the radiator temperature sensor) has failed.

 

P5 - DC sensor defective

 

P6 - output DC / AC sensor defective

 

P7 - input current (in multisystem) is increased

 

PJ - outdoor unit, performance is incorrectly set

System:

 

U0 - reduced pressure in the system due to lack of gas

 

U1 - phases are incorrectly connected (phases must be changed)

 

U2 - low voltage in the power supply

 

U3 - common error in data transfer

 

U4 - communication failure between outdoor and indoor units

 

U5 - communication failure between the remote control and the indoor unit

 

U6 - communication failure between the main and subordinate indoor units

 

U7 - communication failure between the battery or outdoor units

 

U8 - communication between control panels is broken

 

U9 - communication with another system is broken

 

UA - the parameters of the outdoor unit

 

UH - address not entered (outdoor / indoor unit)

 

UC address is set incorrectly on the CPU

 

UJ - communication with peripheral equipment is broken

 

UE - communication failure between the CPU and the indoor unit

 

UF - incorrect installation: wiring / piping

 

M1 - the printed circuit board (central control equipment) is faulty

 

M8 - communication failure with equipment

 

MA - connection of equipment

 

MC - dual assignment of equipment address

Other errors:

 

31 - circulating air humidity sensor defective

 

32 - Outside air humidity sensor defective

 

33 - Supply air sensor defective

 

34 - circulating air temperature sensor defective

 

35 - Outside air temperature sensor defective

 

36 - the temperature sensor of the control panel is defective

 

3A - Water leakage sensor No. 1 is defective

 

3H - water leakage sensor No. 2 defective

 

3C - dew condensation sensor defective

 

40 - humidifier valve defective

 

41 - cold water valve faulty

 

42 - hot water valve faulty

 

43 - cold water heat exchanger defective

 

44 - hot water heat exchanger defective

 

51 - the supply air fan motor is overloaded

 

52 - circulating air fan motor is overloaded

 

53 - Inverter power failure

 

54 - Inverter air flow disturbed

 

60 - general error

 

61 - PCB is defective

 

62 - Inadmissible ozone concentration

 

63 - contamination sensor defective

 

64 - room temperature sensor is defective

 

65 - Sensor for external air temperature monitoring system defective

 

68 - high voltage system failed

 

6A - the damper damper of the system has failed

 

6H - the door switch is open

 

6C - Humidifier element requires replacement

 

6J - High-efficiency filter requires replacement

 

6E - Odor removal catalyst requires replacement

 

6F - simplified control panel defective