To restart the unit, set the mode switch for two seconds to the Reset position. If this device works again, contact a specialist. The ability to make only five attempts to restart the unit, after that it is blocked. To take a new attempt to restart the boiler, it is required to turn it off for a few seconds.
Error E01 - No ignition - Press and hold the Reset button (R) for at least two seconds.
Error E02 - The safety thermostat has switched on for overheating - Press and hold the Reset button (R) for at least two seconds.
Error E03 - A safety thermostat of the protection (thrust sensor) / pressure switch - thrust sensor has occurred.
Error E04 - Failure of frequent flame failure.
Error E05 - Malfunction of the temperature sensor of the heating circuit.
Error E06 - Malfunction of the hot water temperature sensor (NTC).
Error E10 - The hydraulic pressure switch does not give a signal. Check that the system pressure matches the required values.
Error E12 / E13 - Hydraulic pressure problems.
Error E25 / E26 - There is no water circulation (pump blockage).
Error E31 - Communication failure between the unit and the control unit.
Error E32 - Pollution or scale in the boiler system.
Error E35 - Incorrect flame (parasitic flame).
Error E97 - Power failure.
Error E96 - Undervoltage in the electrical supply network - Automatic reset.
Error E98 / E99 - Fault, if detected, it is required to replace the automation system.
De Dietrich Gas Boiler Errors.
E00 - The electronic board is not connected.
E01 - Incorrect protection parameters.
E02 - Short circuit of the heat exchanger sensor.
E04 - The heat exchanger temperature is lowered.
E05 - The heat exchanger temperature is too high.
E06 - Short circuit of the return line sensor.
E07 - Return line sensor fault.
E08 - The return temperature is too low.
E09 - The temperature of the return line is raised.
E10 - The difference between the heat exchanger temperature and the return temperature is too small.
E11 - The difference between the return temperature and the heat exchanger temperature is too high.
E12 - The maximum temperature of the unit has been exceeded (Limit thermostat STB).
E14 - Five failed attempts to start the burner.
E15 - The cyclic leak test unit (CCG) has detected a leak.
E16 - Definition of a parasitic flame.
E17 - Malfunction of the gas valve.
E32 - Short circuit of the machine's flow sensor.
E33 - Supply line sensor interrupted.
E34 - The fan does not rotate at the wrong speed.
E35 - Feed and return lines are reversed.
E36 - The flame was lost more than five times in 24 hours during the burner operation.
E37 - Lost connection with the electronic board SU.
E38 - Communication error with the SCU electronic board.
E39 - Blocking input in lockout mode.