Kiturami Gas Boiler Error Codes

If no lights on the room console - check that the boiler is on the control panel and press the "On / Restart" button. If the situation has not changed - check the voltage regulator and the presence of voltage in the sockets. (Turn the boiler into an outlet without a voltage regulator, plug in an iron or other electrical appliance.)


Malfunction

Methods of elimination

 

The room temperature controller works in normal mode, but the room does not get warmer.

Malfunction of the circulation pump of the boiler.

 

"01", "02", "03" are flashing

1. No ignition occurs due to problems in the flame detector, or immediately after the ignition, a safety trip occurs. It is necessary to wipe the flame detector (photosensor).

2. Check the voltage at the stabilizer 220V + -5%.

3. Check the presence of fuel and its supply to the boiler.

4. Press the "Restart" button on the room console - restart the boiler.

 

"04" flashes

1. Malfunction of the water temperature sensor in the boiler.

2. Press the "Restart" button on the room console - restart the boiler.

 

"08" flashes

1. Too long a distribution network connection with the room temperature controller (more than 10m) or the closure of the telephone wire. If possible, it is worth reassessing the distribution network.

2. Press the "Restart" button on the room console - restart the boiler.

 

Flashing "95"

1. Insufficient water in the boiler - add water to the heating system (the pressure should not exceed 2.0 bar).

 

"96" flashes

1. If the temperature of the heating water is too high due to the operation of the overheating protection device, for safety reasons the boiler is switched off - at this time the circulation pump is running, the water temperature in the heating system is lowered.

 

Flashing "98"

1. Check if there is enough fuel, whether it enters the boiler.

 

"00" flashes

1. Malfunction of the room console or the wire to it.

2. Press the "Restart" button on the room console - restart the boiler.

 

"10" flashes

1. Contamination of the room console.

2. Press the "Restart" button on the room console - restart the boiler.

 

"11" flashes

1. Air pollution in the room (increase in carbon monoxide). The room needs to be ventilated.