E1 - EEPROM error (internal non-volatile memory)
E2 - zero-crossing signal error
E3 - internal fan motor fault
E5 - internal air temperature sensor T1 closed / torn
E6 - evaporator temperature sensor T2 closed / torn
E7 - Condenser temperature sensor T3 closed / torn
EC-Refrigerant leakage
E8 - fan error of outdoor unit fan or wrong phasing of external unit power supply
E9 - connection error between indoor and outdoor units
Models
MVUH252A-VA3
MVUH280A-VA3
MVUH335A-VA3
MVUH400A-VA3
MVUH450A-VA3
E0-outdoor unit connections are faulty, only for slave units
E1 - wrong sequence of phases
E2 - connection between the outdoor unit and the indoor unit
E3 -reserved
E4 - the temperature sensor is defective
E5 -reserved
E6 -reserved
E7 -reseved
E8 is the wrong address of the outdoor unit
E9 - the supply voltage is not normal
H0 is the connection between IR341 and 780034
H1 connection between 0537 and 780034
Models
MS11MU-09HRDN1 MS11MU-12HRDN1
MS11MU-18HRDN1 MS11MU-24HRDN1
MO11MU-09HRDN1 MO11MU-12HRDN1
MO11MU-18HRDN1 MO11MU-24HRDN1
E0 - EEPROM error (nonvolatile memory) of the indoor unit
E1 - connection error between indoor and outdoor units
E2 - zero-crossing signal error
E3 - the error of the engine of the fan of the indoor unit
E4 - indoor temperature sensor closed / broken
E5 - Evaporator temperature sensor closed / broken
EC-Refrigerant leakage
MSX 07 - MSX 18
MSX 21 - MSX 24
E1 - EEPROM error
E2 - zero current leakage
E3 - fan error of the indoor unit - there is no response from the Hall sensor of the electric motor
E4 - the starting current is exceeded when trying to start more than four times in a row
E5 - indoor unit air temperature sensor error
E6 - evaporator temperature sensor error
E7 - condenser temperature sensor error
E8 - phase reversals
E9 - Connection error between indoor and outdoor units
For inverter models
E0 - EEPROM error
E1 - incorrect interconnection (between indoor and outdoor unit)
E2 - wrong connection of the null phase
E3 - malfunction of the indoor fan motor
E4 - reserve
E5 - short-circuited, temperature sensor of the outdoor unit is cut off
E6 - short-circuited, internal temperature sensor is broken
P0 - overburning, power module defective (IPM)
P1 - voltage supply is not normal (high, low)
P2 - high discharge temperature
P3 - the outdoor temperature is too low for the air conditioner to work
P4 -the compressor is faulty