Code
Cause
Place of verification
01
No ignition
1.Fuel and fuel system 2. flame sensor 3. filter and gear pump
02
Quasi Flame
1. flame sensor 2. regulator
03
Temp-ra, deviation. From the norm
Remote control sensor
1. control panel (room temperature controller) 2. regulator
04
Overheat
1. clogged pipes 2. circulation pump 3. temperature sensor 4. regulator
5. bimetal switch from overheating
05
Thermistor, deviation. From the norm
1. temperature sensor (thermistor) 2. regulator
06
Abnormal communication state
1. cable (damaged wires, short circuit) 2. control panel (room temperature controller) 3. regulator
07
Low water level
1. Water access is blocked, or water supply pipes are closed. 2. check the ground wires 3. low water level sensor 4. regulator
08
Water leak
1. water leakage from the pipes 2. water access blocked or water supply pipes closed 3. check the ground wires 4. low water level sensor 5. the water regulating valve (automatic water make-up valve) is clogged or abnormal operation of the water adjusting valve 6. Regulator
09
Full freezing
1. freezing of the room heating circuit and heat exchanger 2. temperature sensor 3. regulator
In the event of an emergency, the ON lamp on the control panel display flashes.
* In case of more than two errors, the codes overlap. In this case, after solving one problem, the other is output. The error code flashes at intervals of 0.5 seconds.
Problem
Place of verification
Measures to eliminate
Smell of exhaust gas
Is the exhaust pipe installed correctly? Is the exhaust pipe clogged? Is the supply and exhaust port clogged?
Check the installation according to the instructions. Clean the exhaust pipe. Clean the hole
Soot and smell
Is the damper installed correctly? Is the deflector
Check the position of the burner flap. Clean the deflector
No ignition
Is the power switched on? Is the control panel indicator blinking? Is the fuel
Turn the power on. Contact the repair service.
Noise of the electronic pump
Is there enough fuel in the fuel tank Is the air sucked
Carry out fuel refueling Remove air from the fuel pipe (figure 10 in the manual)
Noise in other parts
Air in pipes Is the boiler installed correctly?
Remove air from all pipes by opening each outlet valve of the distribution valves for room heating. Check the correct location of the boiler * contact the repair service if it is impossible to eliminate the cause yourself.
The boiler quickly extinguishes after ignition
The fuel is mixed with water. The flame sensor is covered with soot or dust. Is there enough fuel? Is the fuel filter clogged? Is the exhaust pipe installed correctly?
Replace the fuel and blow out the air Clean the flame sensor. Refuel the fuel. Reinstall the exhaust pipe. Clean or replace the fuel filter
No heating
Is the heating / DHW button correctly set? Is the control valve open? Is the heating temperature set at a low elevation? The distribution valves are opened correspondingly with the room size Is there air removal
Select the heating mode. Open the control valves. Adjust the heating temperature. Adjust the opening conditions of the control valves, depending on the size of the room. Remove air from the pipe
No hot water supply
Is the water supply valve open? Is the volume of hot water used too large
Open the water supply valve. Adjust the amount of hot water
Hot water temperature not high enough
Is the volume of hot water used too high Is water used in two or more places at the same time Is the water supply pressure too high
Adjust the water supply by turning the tap Do not use water at the same time in two or more places Reduce the water supply pressure to 2 kg / cm2 or less (you need to install a valve that reduces water pressure)
No ignition
Is there enough fuel in the fuel tank Is the intermediate fuel valve open? Is there no air in the fuel pipes? The fuel filter is clogged with foreign matter. Is the flame sensor correctly installed
Carry out fuel refueling Open intermediate fuel valve Remove air from the electronic pump. Clean or replace the fuel filter. Clean the flame sensor and install according to the instructions
The indicator lamp of the temperature indicator flashes and the control panel does not work
Check whether there is a short circuit or damage to the control panel wires. Is the operation lamp of the control panel flashing
Select the "emergency operation" switch on the top of the main regulator and contact the repair service. Change "emergency work" to "normal operation" (after the emergency work is completed)