SUB-ZERO 400 series Error Codes
05 Upper Cabinet Thermistor read open / short for 10+ seconds, or repeatedly erratic temp’s.
06 Upper Evap. Thermistor read open / short for 10+ seconds, or repeatedly erratic temp’s.
07 Lower Cabinet Thermistor read open / short for 10+ seconds, or repeatedly erratic temp’s.
08 Lower Evap. Thermistor read open / short for 10+ seconds, or repeatedly erratic temp’s.
10 Upper Cabinet Warm Temperature alarm
11 Upper Cabinet Cold Temperature alarm
12 Lower Cabinet Warm Temperature alarm
13 Lower Cabinet Cold Temperature alarm
15 Sealed System Fault (evap temp. cannot drop 5° in 5 minutes, 3 consecutive valve activations)
30 SERVICE (Illuminated) 2 hour thermistor temperature average (at left) with index number. Number 1 is most recent 2 hour period. - Press WARMER key in multiple keystrokes to toggle up through indexes, from 1 to 168.
50 Excessive Refrigerator compressor run
60 4 hour compartment temperature average (at left) with index number. Number 64 is oldest recorded 4 hour period. - Press COLDER key in multiple keystrokes to toggle down
through indexes, from 64 to 1.
66 BELL ON Illuminated indicates power failure / interruption.
68 SERVICE illuminated indicates unit was switched off with UNIT ON / OFF key
SUB-ZERO 600 series Error Codes
05 Refrig. Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
06 Refrig. Evaporator Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
07 Freezer Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
08 Freezer Evaporator Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
20 Defrost Underheat with No Voltage Feedback Through Gray / White Wire at Defrost Start
21 Defrost Overheat
22 No Voltage Feedback Through Gray / White Wire at Defrost Start
23 Defrost Overheat with No Voltage Feedback through Gray / White Wire at Defrost Start
24 Defrost Underheat
30 Excess IM Water Valve Solenoid Activation (> 15 Seconds)
40 Excessive Freezer Comp Run
50 Excessive Refrigerator Comp Run
SUB-ZERO 700 series Error Codes
05 Ref. cabinet therm. read open, short or erratic temp for 10+ sec’s
06 Ref. evap. therm. read open, short or erratic temp for 10+ sec’s
07 Fre. cabinet therm. read open, short or erratic temp for 10+ sec’s
08 Fre. evap. therm. read open, short or erratic temp for 10+ sec’s
20 Defrost underheat & no feedback thru Gr/Wh wire at defrst start
21 Defrost overheat
22 No feedback thru Gr/Wh wire at defrost start
23 Defrost overheat & no feedback thru Gr/Wh wire at defrost start
24 Defrost underheat
80 High VS compressor differential pressures or low voltage supplied to VS compressor
81 High Amperage Draw at VS compressor
82 VS comp. couldn’t maintain min. speed at highest current draw
83 Locked VS compressor Rotor
84 Short circuit at VS compressor controller output circuit
85 VS compressor inverter overheated & shut down VS compressor
86 Serial communication failure between VS compressor controller and electronic control board
87 Speed information from electronic control board is out of spec.
88 Electronic control board not receiving status data in response to speed commands
SUB-ZERO 648 PRO & ICB648 PRO Error Codes
EC ZONE SERVICE INSTRUCTION
01 X Zone “X” Cabinet Thermistor Failure (Device or Wiring)
02 X Zone “X” Evaporator Thermistor Failure (Device or Wiring)
03 X Zone “X” Condenser Thermistor Failure (Device or Wiring)
04 0 Ambient Thermistor Failure (Device or Wiring)
20 X Check Zone “X” Defrost Bi-metal for Proper Operation
21 X Check Zone “X” Defrost Bi-metal for Proper Operation
22 X Check Zone “X” Defrost Wiring
23 X Check Zone “X” Defrost Wiring
24 X Check Zone “X” Defrost Heater Ohms
30 0 Check for Stuck Icemaker or Water Valve Failure
35 X Check Zone “X” Fan, Fan Speed Error
40 X Zone “X” Excessive Run
41 X Check Zone “X” Compressor and Wiring
42 0 Check Condenser Fan and/or Wiring
43 X Check Left Refrigerant Valve and Wiring
44 X Check Zone “X” Glass Door Heater and Wiring
45 X Errors Detectable with Red Door Switches-Disabled Now. Check Overhead Lighting
46 0 Check Ice Accessory Wiring for Open Circuit
47 3 Check Accent Lighting Wiring for Short Circuit
80 X Check Power to Compressor Controller for Zone “X”, Troubleshoot with Manual Activation Mode
83 X Replace Zone “X” VS Compressor and Filter-Drier
84 X Check Zone “X” VS Compressor Wiring
85 X Zone “X” VS Compressor Control Overheat
86 X Check Communication Wiring, Replace Zone “X” VS Controller
87 X Check for Broken Wiring or Open Defrost Heater
89 X Check Icemaker Solenoid Valve and Wiring
90 X Change Main Control Board
92 0 Check Keypad Wiring
93 0 Replace Keypad
94 1 Check Wiring / Replace User Display #1
94 3 Check Wiring / Replace User Display #2
96 0 Datalogger Malfunction
97 0 Check Communications Cables / Connectors
98 0 Brownout Check Input Power Supply