Error 01 - There is no flame on the burner. In the beginning, the device makes three attempts to flare up independently, in case it is connected to liquefied gas, this procedure is given two attempts. In this case, the unit shows the actual water temperature in the heating system. If all attempts are unsuccessful, then the device is installed by accident and blocked. The display shows error code 01. The red light D4 starts to blink. This problem is most often caused by a lack of gas. Therefore, you need to make sure that there is a supply, and if the gas cock is open.

 

Error 02 - This fault occurs when the water temperature in the heat exchanger is above 95 degrees Celsius. In this case, the unit performs the following actions: Stopped by an accident followed by a lockout. The error code 02 is displayed on the display. The red light D4 starts blinking.

 

Error 03 - It appears in the absence of a vacuum pressure in the chimney. The device is stopped by an accident with subsequent blocking. Error code 03 is displayed on the display. The D4 lamp lights up and blinks. This fault is the protection of the boiler, it is described in detail in its instruction manual.

 

Error 04 - This fault occurs when the heating water temperature sensor breaks down. If this error occurs, the machine stops. The error code indicator 04 lights up on the display. The red light D4 starts blinking. After the problem is eliminated, the device starts up and starts working in the standard mode.

 

Error 06 - This fault occurs in the event of a fault in the electrical circuit of the instrument. The device stops by an accident. The error code indicator 06 lights up on the display. The red light D4 flashes. Repair of this problem is carried out by specialists from the service department.


Error 07 - The gas modulator circuit is faulty. With this fault, the unit goes into minimum power mode, but continues to operate. The display shows the value 07. The red light D4 flashes. After the cause of the failure is eliminated, the Termet boiler starts operating in the standard mode.

 

Error 08 - This fault occurs when the water pressure transducers of the central heating heating circuit fail. The appliance switches off the burner. The pump continues to run for another three minutes. The error code 08 is displayed on the display. The red light starts blinking constantly. After the cause of the problem has been eliminated, the unit starts up and works again in the standard mode.

 

Error 09 - This fault indicates an incorrect set pressure in the central heating system. If the pressure is greater than 2.8 Bar, the controller commands the burner to shutdown, and the pump continues to run for three minutes. If the pressure is less than 0.5 bar, the controller gives the command to turn off the burner. The display shows error code 09. The red LED is constantly blinking. At a pressure value less than 0.5 bar, it is necessary to measure the density of the central heating water installation.

 

Error 10 - This fault indicates a problem in the NTC WAN sensor circuit. The appliance switches off. The red light starts blinking continuously.

 

Error 11 - The control system is not properly connected to the power wire. To solve the problem, it is necessary to make the correct connection to the power supply.

 

There's the Termet Gas Boiler Error Codes List